Dialogic
®
4000 Media Gateway Series Reference Guide
Page 108
To configure the PSTN-specific parameters, click Details at the right of the controller connected to the
PSTN line, and configure the following parameters:
Dialplan: Select the dialplan you configured for the PSTN
Type of number (outbound): Select National number.
Encoding (outbound): Select Use prefixes.
Click OK to save the settings and close the window.
12. Under Network Interfaces, enable your Ethernet adapter, and set the SIP listen ports to 9803.