Rev date: 07/05/2011
Innovation Voice Mail
PBX Installation and Testing Guide
Nortel Meridian 1 M2616
Integration using Dialogic Media
Gateways
1841 Bourbon Road
Cross Plains, Wisconsin
1-800-424-6757
www.innovationtw.com
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Gateways

Rev date: 07/05/2011 Innovation Voice Mail PBX Installation and Testing Guide Nortel Meridian 1 M2616 Integration using Dialogic Media Gateways

Page 2 - Dialogic Media Gateways

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 9 SEVENTH VM PORT (DN 5006) DES 5006 TN 004 0 00 14 TYPE 2616 CDEN 8D C

Page 3

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 10 EIGHTH (LAST) VM PORT (DN 5007) DES 5007 TN 004 0 00 15 TYPE 2616 CD

Page 4

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 11 NETWORK CONNECTIONS: INSTALLATIONS WITH ONE GATEWAY (8 ports or less) On t

Page 5

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 12 INSTALLATIONS WITH MULTIPLE GATEWAYS (more than 8 ports) Connect a network

Page 6

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 13 PBX TERMINATIONS: The Dialogic DMG1008DNI has 8 RJ14 style connectors on t

Page 7

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 14 VOICEMAIL PROGRAMMING: InnLine IP Configuration Utility (IIPConfig) On the

Page 8

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 15 Voice Port Configuration Go to Do > Configure System > Voice Ports a

Page 9

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 16 DIALOGIC MEDIA GATEWAY PROGRAMMING: You will need to program all the stati

Page 10

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 17 PROGRAM STATION NUMBERS FOR VOIP AUTHENTICATION Program the voicemail DN’s

Page 11

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 18 DEVICE INTERFACE CONNECTIONS: Connecting the voicemail system to both the

Page 12 - NETWORK CONNECTIONS:

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 1 Nortel Meridian 1 M2616 Integration using Dialogic Media Gateways REQUIREM

Page 13

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 19 TESTING: Testing direct call integration (staff or guest extension) Fro

Page 14 - PBX TERMINATIONS:

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 20 Enter a valid extension number and test turning the message lamp on and off

Page 15 - VOICEMAIL PROGRAMMING:

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 21 PBX side of the interface Check-in message example Check-out m

Page 16 - Voice Port Configuration

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 22 Changing out InnLine systems that used a D/82U integration board If the vo

Page 17

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 2 LD 95 Call Party Name Display: When the Meridian 1 PBX forwards a call, it d

Page 18

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 3 2616 DN programming: Create a 2616 type DN for each voicemail port. The prog

Page 19

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 4 SECOND VM PORT (DN 5001) DES 5001 TN 004 0 00 01 TYPE 2616 CDEN 8D CUST

Page 20 - TESTING:

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 5 THIRD VM PORT (DN 5002) DES 5002 TN 004 0 00 02 TYPE 2616 CDEN 8D CU

Page 21 - Click here to view the

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 6 FOURTH VM PORT (DN 5003) DES 5003 TN 004 0 00 03 TYPE 2616 CDEN 8D CU

Page 22

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 7 FIFTH VM PORT (DN 5004) DES 5004 TN 004 0 00 10 TYPE 2616 CDEN 8D CUST

Page 23

Innovation Voice Mail PBX Installation and Testing Guide 07/05/2011 8 SIXTH VM PORT (DN 5005) DES 5005 TN 004 0 00 11 TYPE 2616 CDEN 8D CUS