SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.11.8 RDPRI – Remote Data Centre Periodic Report Initiate
Synopsis
This command initiates a report collection period for which data is collected and transferred over Ethernet to
a Remote Data Centre (RDC).
Reports for outgoing route traffic measurements can be specified.
The label is used as the directory name on the RDC that the files are written to.
The period is the interval between which data is collected. It is rounded to the nearest 5-minute interval.
Data can be added or deleted from the periodic report using the RDPDI or RDPDE commands.
Syntax
RDPRI:REPORT=,PRTYPE=,PERIOD=,LABEL=,RDC1=,[RESET=,][RDC2=,];
Prerequisites
The report has not already been initiated.
If specified, RDC2 cannot have the same value as RDC1.
RDC1 must already have been initiated.
If specified, RDC2 must already be initiated.
Limitations
Before transfer to an RDC can take place, the directory (represented by the label) must exist on the remote
site.
Attributes
CONFIG
Examples
RDPRI:REPORT=1,PRTYPE=MSC7,PERIOD=01:00:00,RDC1=1,LABEL=SS7;