126 Dialogic
®
1000 and 2000 Media Gateway Series User’s Guide
Parameter Reference
3.9.1 Timing Group
The Analog parameters in the Timing group include:
Flash Hook
Loop Current Off Debounce
Incoming Rings Before Answer
Ringing Timeout
3.9.1.1 Flash Hook
Description: Specifies the duration in milliseconds that the DMG1000 will remain on-hook during
a hook flash operation.
Allowed Values: 50 to 4000 milliseconds
Default Value = 500 milliseconds
INI File Parameter Name = telFlashMs
3.9.1.2 Loop Current Off Debounce
Description: Specifies the time in milliseconds that loop current can be removed by the PBX on an
active call before the DMG1000 considers the line disconnected.
Allowed Values: 500 to 10000 milliseconds
Default Value = 2500 milliseconds
INI File Parameter Name = telLCOff
3.9.1.3 Incoming Rings Before Answer
Description: Specifies the number of ring bursts that must be present at the DMG1000 before the
call is presented to the IP destination as a new call.
Allowed Values: 1 to 100
Default Value = 1
INI File Parameter Name = telIncomRing