Dialogic DSI SS7MD Manuel d'utilisateur Page 130

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 191
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 129
130
7 Configuration Command Reference
set to 0, on detection of RPO, the signaling link is taken out of service and restoration commences.
This bit should normally be set to 1.
Bit 20 used in conjunction with bit 9 to select point codes (see table above).
Bit 21 should be set to 1 for use in Japanese networks; otherwise it should be set to 0.
All other bits are reserved for future use and should be set to 0.
Note: For correct ANSI operation, bits 8, 9, 10, 11 and 18 must be set to 1. This gives a typical
<options> field value of 0x00040f00.
Vue de la page 129
1 2 ... 125 126 127 128 129 130 131 132 133 134 135 ... 190 191

Commentaires sur ces manuels

Pas de commentaire