114
6 Message Reference
receiver_busy_cnt
The number of times the receiver has entered the busy state as a result of the number of internal buffers
falling below a set threshold.
rx_frame_cnt
The number of (error-free) frames received on the link, excluding any duplicate frames that are
discarded as a result of the internal filtering mechanism.
rx_pre_filter_cnt
The total number of (error-free) frames received on the link including any duplicate frames that are
discarded as a result of the internal filtering mechanism.
tx_frame_cnt
The number of frames transmitted on the link excluding any repeated frames that are generated
automatically (for example, repeated FISUs or LSSUs).
rx_busy_status
Normally set to 0, but in the event of the receiver being in the a “busy” state (where the number of
internal buffers falls below a fixed internal threshold), this field is set to 1.