Dialogic DSI SPCI Network Interface Boards Manuel d'utilisateur Page 67

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 111
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 66
Dialogic
®
DSI SPCI Network Interface Boards Programmer's Manual Issue 5
67
6.3.8 Fixed Data Output Request
Synopsis:
Message sent to the DSI SPCI Board in order to generate a fixed pattern on a
specific T1/E1 Line Interface Unit timeslot.
Message Format:
MESSAGE HEADER
Field Name Meaning
type MVD_MSG_SC_FIXDATA (0x7e15)
id
0
src
Sending Module ID
dst MVD_TASK_ID (0x10)
rsp_req
Used to request a confirmation
hclass
0
status Status Response (if confirmation requested)
err_info
0
len
6
PARAMETER AREA
Offset Size Name
0 2 liu_id
2 2 timeslot
4 2 pattern
Description:
This message is sent to the DSI SPCI Board in order to generate a fixed
pattern on a specific timeslot of an T1/E1 Line Interface Unit. It is typically
issued at initialization and whenever a call terminates to generate an IDLE
pattern towards the network.
Parameter Description:
liu_id
The identifier of the T1/E1 Line Interface Unit in the range 0 to one less than
the number of LIUs fitted.
Note: For the SPCI2S, valid values for the LIU identifiers are 2 and 3.
Vue de la page 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 110 111

Commentaires sur ces manuels