Vue de la page 44
Dialogic
®
DSI SS7MD Network Interface Boards Programmer's Manual Issue 4
45
Value
Description
0
Do not change AIS/Blue alarm generation mode
1
Disabled; do not generate AIS/Blue alarm
2
Enabled; generate AIS/Blue alarm
loop_mode
The diagnostic loopback mode. The following table shows the permitted values and
their meanings.
Value
Description
0
Do not change diagnostic loopback mode
1
Disabled - remove any diagnostic loop
2
Payload loopback
3
Remote loopback
4
Local loopback
prbs_gen
The Pseudo Random Bit Sequence (PRBS) generation mode. The following table shows
the permitted values and their meanings.
Value
Description
0
Do not change PRBS generation mode
1
Disabled - remove any PRBS generation
3
Generate PRBS pattern QRSS 20